Disposal, the final processor and small appliance safety
By the end of this lesson you can:
- Know who must make sure refrigerant is removed before scrapping
- Write or check a recovery statement
- Service flammable small appliances safely
The final processor's duty
The person who takes the appliance last in the disposal chain (a scrap recycler or landfill operator) must make sure the refrigerant has been recovered. They can recover it themselves with certified equipment and trained staff, or accept the appliance with proof that someone else already did.
That proof is commonly a signed statement with the name and address of the person who recovered the refrigerant and the date.
Refrigerants you will meet
| Era | Typical refrigerant |
|---|---|
| Household refrigerators before the mid-1990s | R-12 (CFC) |
| Most refrigerators from the 1990s on | R-134a (HFC) |
| Many newer refrigerators | R-600a (isobutane, A3) |
| Some newer small appliances | R-290 (propane, A3) |
Flammable refrigerants
- Work in a well-ventilated area with no ignition sources nearby.
- Use tools and recovery equipment rated for flammable refrigerants.
- Follow the manufacturer's service instructions; many A3 appliances are marked with red tubing or labels.
Other checks
- Check a recovery cylinder for air: let it reach room temperature, then compare its pressure with a PT chart.
- Label each cylinder with the refrigerant inside.
Numbers to know
| R-12 → R-134a → R-600a | How household refrigerator refrigerants changed |
Key terms
| Final processor | Last person in the disposal chain, such as a scrap recycler. |
| Recovery statement | Signed proof of who recovered the refrigerant, where and when. |
Exam traps
- Thinking the original owner, not the final processor, must verify recovery
- Treating R-600a like a nonflammable refrigerant
Summary
- The final processor makes sure refrigerant is gone before scrapping
- A signed statement names who recovered it and when
- R-600a and R-290 are flammable: ventilate, no ignition sources
Quick check
Pick an answer to see the explanation.
Who is responsible for making sure refrigerant has been removed before a small appliance is scrapped?
Answer: The person who takes the final step in the disposal chain, such as the scrap recycler. The final processor in the disposal chain, such as a scrap metal recycler or landfill, must make sure refrigerant was recovered. They often do this with a signed statement from the supplier.
Where is the best place to find which refrigerant a small appliance uses?
Answer: The appliance nameplate or data plate. The nameplate or data plate lists the refrigerant type and charge. Always check it so you use the right recovery cylinder and avoid mixing refrigerants.
How can you check a recovery cylinder for air (non-condensables)?
Answer: Let the cylinder reach room temperature and compare its pressure with a pressure-temperature chart. At a stable temperature, pure refrigerant shows the pressure listed on a PT chart. If the reading is higher, non-condensables such as air are likely present.
What should be done to a new recovery cylinder before its first use?
Answer: Evacuate it to remove air. Evacuating a new or empty recovery cylinder removes air, so non-condensables are not mixed with the recovered refrigerant.
Which certification does a technician need to recover refrigerant from small appliances?
Answer: Type I or Universal. Type I certification covers small appliances. Universal certification covers Type I, Type II and Type III.
Keep going in the Type I practice test
Practice Type I10 new free questions a day. Missed ones come back first.
Written by the Pass608 team from 40 CFR Part 82, Subpart F. How we check it · Report a mistake